Yokogawa 701265 High-Precision Temperature Input Module
Category - High Speed Data Acquisition
Get a price
FAMAGA always strives to provide the best prices and timings of supplies for its customers. We sell only original equipment and spare parts, although we are not always the official distributor or manufacturer's dealer. All displayed trademarks and part numbers are the property of their respective owners.
Our array of items consists of huge number of goods of the Yokogawa. Yokogawa produces dynamic and innovative products that always find the solution for the tough industrial problems at any time. The Yokogawa achieves the high standards of equipment performance while creating the modern technologies that improve the work cycle of the industries. The Yokogawa Yokogawa 701265 High-Precision Temperature Input Module is one of the masterly designed items. Yokogawa Yokogawa 701265 High-Precision Temperature Input Module presents high degree of precision, which offer wide range of automatic and electric resolutions to fulfill all application needs. Because of the high quality of constituents, Yokogawa Yokogawa 701265 High-Precision Temperature Input Module ensure long time of use.
As the greatest industrial provider of various brands, we always committed to establish splendid experience to our purchasers by offering huge number of industrial outfit and constituent parts at affordable prices with the brilliant chain of supply in the brief period of time. A top level of determination permit us to distribute any shape of product in the quickest period of time and respond the needs of our consumers in the processing sector. As for the charges and transit period, please fill in the form or submit your order to sales@famaga.us">sales@famaga.us
As the greatest industrial provider of various brands, we always committed to establish splendid experience to our purchasers by offering huge number of industrial outfit and constituent parts at affordable prices with the brilliant chain of supply in the brief period of time. A top level of determination permit us to distribute any shape of product in the quickest period of time and respond the needs of our consumers in the processing sector. As for the charges and transit period, please fill in the form or submit your order to sales@famaga.us">sales@famaga.us


Description
Temperature/high-precision voltage Module (2 ch) Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (0.1mV/div), and low noise (±4 µ,Vtyp.) Applicable to DL350, DL850 series, DL750 series and SL1000.Item | Specifications | ||||||||||||||||||
Standard operating conditions | Temperature: 23 ±5°C Humidity: 20% to 80% RH After a 30-minute warm-up and after calibration | ||||||||||||||||||
Function | Temperature (thermocouple) or voltage measurement (switchable) | ||||||||||||||||||
Number of input channels | 2 | ||||||||||||||||||
Input coupling | TC, DC, and GND
| ||||||||||||||||||
Data update rate | 500Hz | ||||||||||||||||||
Measurement range/accuracy1 | [Voltage measurement] Voltage sensitivity: 100 µ,V/div to 10 V/div (1-2-5 steps) Voltage accuracy: ±(0.08% of 10 div + 2µ,V) [Temperature measurement]2
| ||||||||||||||||||
Frequency characteristics1 (–3 dB point when a sine wave of amplitude ±3 div is applied) | [Voltage measurement] DC to 100 Hz [Temperature measurement] DC to 100 Hz | ||||||||||||||||||
Maximum input voltage4 (at a frequency of 1 kHz or less) | Both temperature and voltage input: 42 V (DC + ACpeak) | ||||||||||||||||||
Maximum allowable common mode voltage5 (at a frequency of 1 kHz or less) | Both temperature and voltage input: 42 V (DC+ACpeak) (CAT II, 30 Vrms) | ||||||||||||||||||
Vertical resolution | [Voltage measurement] During voltage input: 2400 LSB/div [Temperature measurement] When measuring temperature: 0.1°C | ||||||||||||||||||
–3 dB point when AC coupled low frequency attenuation point | [Voltage measurement] 0.5 Hz or less | ||||||||||||||||||
Input connector | Binding post | ||||||||||||||||||
Input impedance | Approx. 1 M&Omega, | ||||||||||||||||||
Common mode rejection ratio | [Voltage measurement] 80 dB (50/60 Hz) or more (typical6) [Temperature measurement] 120 dB or more (50/60 Hz, with 2-Hz filter ON, signal source resistance of 500 &Omega, or less) (typical6) | ||||||||||||||||||
Residual noise level (Input section shorted) | [Voltage measurement]: ±4 µ,V or ±0.01 div, whichever is greater (Typical6) | ||||||||||||||||||
A/D conversion resolution | [Voltage measurement] 16 bits (2400 LSB/div) | ||||||||||||||||||
Temperature coefficient | [Voltage measurement] Zero point: ±(0.01% of 10 div)/°C + 0.05µ,V/°C (typical6) Gain: ±(0.02% of 10 div)/°C (typical6) | ||||||||||||||||||
Reference junction compensation accuracy (when the input terminal temperature is balanced) | K, E, J, T, L, U, N: ±1°C R, S, B, W: ±1.5°C Au7Fe: ±1K | ||||||||||||||||||
Bandwidth limit (digital filter) | Select from OFF, 30 Hz, 8 Hz, and 2 Hz | ||||||||||||||||||
Input bias current | 20 nA or less The zero point appears to be offset when the input is open due to the effects of bias current on this module. However, this is not a malfunction. Connect the input to the object to be measured. |